#1 Updated by Hynek Cihlar 8 months ago

This issue was identified during #6615.

FOCUS should only return field-level (frame child widgets or other frames) legacy widgets.

I already created a fix for this, see the checked in file 6615.20220823.diff in #6615. But the changes caused ChUI and GUI regressions. Apparently the rules of FOCUS are more complex than I initially thought.

#3 Updated by Vladimir Tsichevski 1 day ago

  • Related to Bug #8673: Deduce the logic behind OE focus management and implement in FWD added